FUJI AS-Interface_AS-i Masters MastersMICREX-SX
Description

The NP1L-AS2 AS-i master, mounted on the base unit of the MICREX-SX series of SPH, communicates with devices on the AS-i bus.

. Up to 12 AS-i masters can be connected to one SX-bus configuration.
. Up to 62 A/B slaves can be connected.
. Up to 31 analog slaves can be connected.
. Addition of notification function of peripheral error.
. The slaves’ configuration can be registered by a switch on the front of the AS-i master.
. The status of the AS-i bus is indicated by the LEDs on the AS-i master, e.g., showing disconnection of slaves, AS-i power supply failure, and automatic addressing availability.
. The 7-segment LED indicates the addresses of disconnected slaves (in protect mode) and configured slaves (in configuration mode).
. AS-i specification: V2.1
MICREX-SX
NP1L-AS2
(AF00-112)

Ratings and specifications
Type NP1L-AS2
Communications specifications Maximum connectable slaves 62 A/B slaves for V2.1 (addresses 1A to 31A, 1B to 31B)
31 standard slaves for V2.0 (addresses 1 to 31, Analog slaves are treated in the same way as standard slaves.)
Maximum No. of input/output points 434 points (When connecting A/B slaves: 248 input and 186 output points)
248 points (When connecting standard slaves: 124 input and 124 output points)
Network topology Tree, line, and star structure
Max. cable length Up to 100m (extendable up to 300m via repeater)
Transmission speed 167kbps
Transmission cable AS-i cable (yellow), or parallel cable (2 x 1.5mm2)
Cycle time Approx. 10ms (with 62 slaves connected), Approx. 5ms (with 31 slaves connected)
Power supply for communications AS-i power supply (30V DC)
AS-i current consumption 100mA or less
Function specifications No. of slots occupied 1
Maximum connectable AS-i masters 12 per configuration
Internal current consumption (at 24V) 100mA or less
General specifications Insulation resistance 10M or more with 500V DC megger, between external terminals and FG
Dielectric strength 445V AC for 1min, between external terminals and FG
Operating temperature 0 to +55˚C (no icing or no condensation)
Storage temperature -25 to +70°C (no icing or no condensation)
Relative humidity 20 to 95% RH (no condensation)
Pollution degree 2 (no conductive dust)
Atmosphere No corrosive gases, no organic solvent adhering to the master
Vibration resistance Amplitude: 0.15mm, constant acceleration: 19.6m/s2 for 2 hours in each direction
Shock resistance 147m/s2 for 3 times in each direction (Peak acceleration)
Noise immunity Noise simulator method: Rise time 1ns, pulse width 1µs, 1.5kVp-p
Electrostatic discharge resistance Contact discharge method: ±6kV, Aerial discharge method: ±8kV
Degree of protection (IEC 60529) IP30 (installation inside panel)
Cooling method Natural cooling
Mass Approx. 180g
Approval CE